Brand: LS Electric XGB Item: PLC Includes: 3-wire power cable and 5-pin serial communication terminal block Dangerous Goods: Battery Installed: Yes (not user replaceable)Packaging Instructions: 970UN Number: UN3091Hazard Type: Lithium BatteriesBattery Type: CoinLithium Content: 0.01 Port Protocol(s): Modbus RTU Master/SlaveModbus ASCII Master/SlaveModbus TCP Client/ServerLS XGT protocol Client/Serverprogramming and monitoring Communication Port and Connection Type(s): (1) Ethernet 10/100Base-T (RJ45)(1) RS-232/RS-485 (5-pin terminal)(1) miniB-USB Port Speed(s): 10/100 Mbpsup to 115.2k baud Total Memory: 544 KB Requires: XTB-40H terminal block and C40HH-xxSB-XBI cable Load Current: (12) 0.1A/point, (4) 0.5A/point Battery Backup: No External Power Requirement: 24 VDC Discrete Input Type: Sinking/sourcing Discrete Output Type: Sinking Nominal Input Voltage: 24 VDC Nominal Output Voltage: 12-24 VDC Programming Software: XG5000 programming software v4.7 or later Voltage Type: DC Number of Discrete Input Points: 16 Number of Non-Isolated Discrete Input Commons: 1 Number of Points per Discrete Input Common: 16 Number of Discrete Output Points: 16 Number of Non-Isolated Discrete Output Commons: 1 Number of Points per Discrete Output Common: 16 Programming Language: IEC 61131-3 ladder, structured text, sequential function chart and instruction list Maximum Switching Frequency: 200 kHz Number of High-Speed Capable Input Points: 4 Number of High-Speed Capable Output Points: 2 Real Time Clock/Calendar: Yes Frequency Response: 200 kHz High-Speed Counter(s): up to (4) up countersup to (4) down countersup to (2) up/down countersup to (2) pulse/direction (bi-directional) countersup to (2) quadrature (A and B) counters Axis Profile(s): relative/absolute positioningvelocity modetrapezoidS-curveelectronic gearingcammingfollowinghomingjogginginchingteach functionslinear interpolationellipse interpolationhelical interpolationsoftware limit switchesonline editx-y trend view Frequency Measurement: up to (4) up countersup to (4) down countersup to (2) up/down countersup to (2) pulse/direction (bi-directional) countersup to (2) quadrature (A and B) counters Output Pulse Mode(s): up to (2) PTO pulse/direction outputs Program Memory: 384 KB User Data Memory: 160 KB Retentive Memory: Yes Maximum Expansion Modules Allowed: 7 Maximum Number of PID Loops: 16 Interrupt(s): up to (16) cycle time interruptsup to (8) external input interruptsup to (16) internal device interruptsup to (4) high-speed counter interruptsup to (1) positioning interrupt LS Electric XGB PLC, 24 VDC required, Ethernet, serial and USB B ports, Discrete Input: 16-point, DC, Discrete Output: 16-point, sinking, 4 high-speed input point(s), 2 high-speed output point(s). Requires XTB-40H terminal block and C40HH-xxSB-XBI cable.